030101: www.ps.bam.de/DE95/DE95.HTM

Fig. B4 and D4 of chromatic ISO/IEC-test chart 2 and 4
Colour Workflow (CW) by the input operator no. 0(D/I), 1(E/J), 5(F/K)
and different output PS operators and Output Linearisation (OL)

For this page in german without and with MTL code for OL with CIELAB data of surface colours, see DG95
For this page in english without and with MTL code for OL with CIEXYZ data of luminous colours, see IE95
For this page in german without and with MTL code for OL with CIEXYZ data of luminous colours, see IG95

For a previous similar page in english without and with MTL code for OL with CIELAB data of surface colours, see DE94
For a next similar page in english without and with MTL code for OL with CIELAB data of surface colours see DE96


Fig. 1: Output layout without the MTL code in the N-File (N = No MTL code in the file),
see
L95E00N1.PS / TXT / JPG / PDF


Fig. 2: Output layout changed by the MTL code with example "linear"
CIELAB output data in the F-File (F = MTL code in the File)
which produce "equal" output compared to Fig. 1, see
L95E00F1.PS / TXT / JPG / PDF

Remark: In Fig. 2 the output of the grey series in row 4 and 8 is identical and defined by the same grey
output PS operator used in the MTL code. In Fig. 1 the output of the two grey series in row 4 and 8
may be different, because two different input PS operators are used in the N-file.


Fig. 3: Output layout changed by the MTL code with example "quadratic"
CIELAB output data in the F-File (F = MTL code in the File)
which produce"lighter" output compared to Fig. 1, see
Q95E00F1.PS / TXT / JPG / PDF


Fig. 4: Output layout changed by the MTL code with example "square root"
CIELAB output data in the F-File (F = MTL code in the File)
which produce "darker" output compared to Fig. 1, see
S95E00F1.PS / TXT / JPG / PDF

One may use for Output Linearisation (OL) the colour definitions with the input PS operator olv* setrgbcolor or LAB* setcolor instead of the PS operator cmyn* setcmykcolor.

For this page in german with the colours defined by the input PS operator cmyn* setcmykcolor, see DG95
For this page in german with the colours defined by the input PS operator olv* setrgbcolor, see EG95
For this page in german with the colours defined by the input PS operator LAB* setcolor, see FG95

For this page in english with the colours defined by the input PS operator cmyn* setcmykcolor, see DE95
For this page in english with the colours defined by the input PS operator olv* setrgbcolor, see EE95
For this page in english with the colours defined by the input PS operator LAB* setcolor, see FE95

Important properties if the MTL code is used (see files: L..FA.PS, L..FP.PDF, L..SP.PDF):
1. The output is the same for all output PS operators independent of the input PS operator used.
2. The output is the same and visually equally spaced (in CIELAB) for all output PS operators if Output Linearisation (OL) by the MTL code is used (e. g. files [(Q/S/F/O/T)]..FP.[PS/PDF]). The equally spaced output is independent of the input PS operator used.

For information about the parameter i*ptrsc (number 0 to 7) used for input or output PS operators, see DE802

For information about the ISO/IEC-test charts and separate parts (Fig. XY) with different input PS operators and discussion, see DE801

This page includes files for the following application:
Fig. B4 and D4 of chromatic ISO/IEC-test chart 2 and 4,
Colour Workflow (CW) and Output Linearisation (OL)

Table 1 includes the output files of the Portable Document format (L..NP.PS/TXT/PDF and L..FP.PS/TXT/PDF)
Table 2 includes the output files of the PostScript format (L..NA.PS/TXT and L..FA.PS/TXT).
Table 3 includes the output files of the Portable Document format (L..NP.PS/TXT/PDF and L..SP.PS/TXT/PDF).

To indicate the Colour Workflow (CW) at the output different file names are used. The files have usually the same PS content

The PS content of the files L..NP.PS, L..NA.PS and L..SP.PS of the Tables 1 to 3 is identical and includes no MTL code.
The PS content of the files L..FP.PS and L..FA.PS of the Tables 1 and 2 is identical and includes the MTL code L..FP.DAT or L..FA.DAT in the file (F).

The output of the files L..FP.PDF and L..SP.PDF must be identical if the MTL code L..SP.DAT is stored within the Distiller Startup Directory during distilling of the PS file L..SP.PS. The files L..FP.PDF and L..SP.PDF have been produced by the software Adobe Acrobat DIstiller Version 3.0. In the first case the MTL code is located in the file L..FP.PS and in the second case the MTL code L..FP.DAT = L..SP.DAT is not in the file L..SP.PS but in the Startup (S) directory of the software Adobe Acrobat DIstiller.

Input PS operator no. 0(D/I), 1(E/J), 5(F/K)
and start files

*NP.PS / .TXT /.PDF
140 / 140 / 25 kByte
Output
PS operator
parameter
i*ptrsc
Colorimetric transfer from the
input PS operator no. 0(D/I), 1(E/J), 5(F/K)
to the output PS operators no. 0 to 7
defined by i*ptrsc

Output Linearisation with
L=Linear data (no change of scaling of output) in files
*FP.PS / TXT / PDF
240 / 240 / 25 kByte

PostScript MTL code used for output
100 kByte
L95E00NP.PS / TXT / PDF  0 cmy0* setcmykcolor and 000n* setcmykcolor L95E00FP.PS / TXT / PDF L95E00FP.DAT
L95E01NP.PS / TXT / PDF  1 olv* setrgbcolor and w* setgray L95E01FP.PS / TXT / PDF L95E01FP.DAT
L95E02NP.PS / TXT / PDF  2 cmy0* setcmykcolor and nnn0* setcmykcolor L95E02FP.PS / TXT / PDF L95E02FP.DAT
L95E03NP.PS / TXT / PDF  3 olv* setrgbcolor and www* setrgbcolor L95E03FP.PS / TXT / PDF L95E03FP.DAT
L95E04NP.PS / TXT / PDF   4 lab* setcolor L95E04FP.PS / TXT / PDF L95E04FP.DAT
L95E05NP.PS / TXT / PDF  5 LAB* setcolor L95E05FP.PS / TXT / PDF L95E05FP.DAT
L95E06NP.PS / TXT / PDF  6 000n* setcmykcolor L95E06FP.PS / TXT / PDF L95E06FP.DAT
L95E07NP.PS / TXT / PDF  7 w* setgray L95E07FP.PS / TXT / PDF L95E07FP.DAT

Table 1: For PDF output with linearising data in File (F); Input PS operator no. 0(D/I), 1(E/J), 5(F/K) in the NP file and output PS operators no. 0 to 7 in the in FP file which are transferred by the PS MTL code.

Remark: With the files of Table 1 it is intended to produce only a PDF output with linearisation data in the File (F) and not a PS output.

Input PS operator no. 0(D/I), 1(E/J), 5(F/K)
and start files

*NA.PS / .TXT
140 / 140 kByte
Output
PS operator
parameter
i*ptrsc
Colorimetric transfer from the
input PS operator no. 0(D/I), 1(E/J), 5(F/K)
to the output PS operators no. 0 to 7
defined by i*ptrsc

Output Linearisation with
L=Linear data (no change of scaling of output) in files
*FA.PS / TXT
240 / 240 kByte

PostScript MTL code used for output
100 kByte
L95E00NA.PS / TXT  0 cmy0* setcmykcolor and 000n* setcmykcolor L95E00FA.PS / TXT L95E00FA.DAT
L95E01NA.PS / TXT  1 olv* setrgbcolor and w* setgray L95E01FA.PS / TXT L95E01FA.DAT
L95E02NA.PS / TXT  2 cmy0* setcmykcolor and nnn0* setcmykcolor L95E02FA.PS / TXT L95E02FA.DAT
L95E03NA.PS / TXT  3 olv* setrgbcolor and www* setrgbcolor L95E03FA.PS / TXT L95E03FA.DAT
L95E04NA.PS / TXT   4 lab* setcolor L95E04FA.PS / TXT L95E04FA.DAT
L95E05NA.PS / TXT  5 LAB* setcolor L95E05FA.PS / TXT L95E05FA.DAT
L95E06NA.PS / TXT  6 000n* setcmykcolor L95E06FA.PS / TXT L95E06FA.DAT
L95E07NA.PS / TXT  7 w* setgray L95E07FA.PS / TXT L95E07FA.DAT

Table 2: For PS output with linearising data in File (F); Input PS operator no. 0(D/I), 1(E/J), 5(F/K) in the NA file and output PS operators no. 0 to 7 in the in FA file which are transferred by the PS MTL code.

Remark: With the files of Table 2 it is intended to produce only a PS output and not a PDF output.

The files of the tables 1 to 3 are available for different devices instead of the model device L=Linear. Every device produces with all NP files the same start output. Only for the model device L=Linear of the table 2 the output of the NP and FP in one row is identical. For devices which produce equal output for corresponding colours the output of all FP files in one collum is identical.

In application the output of the NP files for differnet output parameters i*ptrsc is in one collum often different. The output of the FP file of the devices S and Q or of the linearized output devices F, O, and T is different compared to the output of the NP file. The PS MTL code uses the measurement data of up to 256 colours of the start output, see the CIELAB LAB* data at the beginning of the FP files, for the change and the linearisation of the output.

There are NP and FP files for the following devices (they are not available at this side for all devices)
S (Model device =Square Root, leads to a lighter output with the FP file), see DE95S
Q (Model device = Quadrac, leads to la darker output with the FP file), siehe DE95Q
F (PS foto printer, leads to a linearized output with the FP file), see DE95F
O (PS laser printer, leads to a linearized output with the FP file), see DE95O
T (PS laser printer, leads to a linearized output with the FP file), see DE95T
If the files are not available then try for similar modifications the directories DE81, DE84, DE85, DE87, DE95, DE96

Input PS operator no. 0(D/I), 1(E/J), 5(F/K)
and start files

*NP.PS / .TXT /.PDF
140 / 140 / 25 kByte
Output
PS operator
parameter
i*ptrsc
Colorimetric transfer from the
input PS operator no. 0(D/I), 1(E/J), 5(F/K)
to the output PS operators no. 0 to 7
defined by i*ptrsc

Output Linearisation with
L=Linear data (no change of scaling of output) in files
*SP.PS / TXT / PDF
240 / 240 / 25 kByte

PostScript MTL code used for output
100 kByte
L95E00NP.PS / TXT / PDF  0 cmy0* setcmykcolor and 000n* setcmykcolor L95E00SP.PS / TXT / PDF L95E00SP.DAT
L95E01NP.PS / TXT / PDF  1 olv* setrgbcolor and w* setgray L95E01SP.PS / TXT / PDF L95E01SP.DAT
L95E02NP.PS / TXT / PDF  2 cmy0* setcmykcolor and nnn0* setcmykcolor L95E02SP.PS / TXT / PDF L95E02SP.DAT
L95E03NP.PS / TXT / PDF  3 olv* setrgbcolor and www* setrgbcolor L95E03SP.PS / TXT / PDF *) L95E03SP.DAT
L95E04NP.PS / TXT / PDF   4 lab* setcolor L95E04SP.PS / TXT / PDF L95E04SP.DAT
L95E05NP.PS / TXT / PDF  5 LAB* setcolor L95E05SP.PS / TXT / PDF L95E05SP.DAT
L95E06NP.PS / TXT / PDF  6 000n* setcmykcolor L95E06SP.PS / TXT / PDF L95E06SP.DAT
L95E07NP.PS / TXT / PDF  7 w* setgray L95E07SP.PS / TXT / PDF L95E07SP.DAT

Table 3: For PDF output with linearising data in Startup (S); Input PS operator no. 0(D/I), 1(E/J), 5(F/K) in the NP file and output PS operators no. 0 to 7 in the in SP file which are transferred by the PS MTL code.

*) Only the PDF file L95E03SP.PS is transferred with the file L95E03SP.DAT which uses the parameter i*ptrsc=3 in the Distiller Startup (S) Directory. The other L..SP files of the Table 3 are distilled with the default file Example.ps in the Distiller Startup (S) Directory.

Remark: With the files of Table 3 it is intended to produce only a PDF output with linearisation data in the Distiller Startup (S) Directory and not a PS output.

The input operator no. 0(D/I), 1(E/J), 5(F/K) and eight output PS operators no. 0 to 7 are used in the files.The input PS operator no. 0(D/I), 1(E/J), 5(F/K) of the NA or NP file are transferred to the output PS operators no. 0 to 7 in the FA, FP or SP file by the PS MTL code.

For further information and discussion of the results in the achromatic case with similar files see DE811

For further information and discussion of the results in the chromatic case with similar files see DE841

Compare the final result in DE811 and DE841. The Colour Workflow (CW) and the Output Linearisation (OL) of the PS MTL code is based on ISO/IEC 15775 and DIS ISO/IEC 19839-X. The PS MTL code is compatible to CIELAB and fulfils the basic user requirements in the field of image technology. The result is the same in the achromatic and chromatic case.

------
The ISO/IEC-test charts according to ISO/IEC 15775 and DIS ISO/IEC 19839-1 to -4 with english text: IE13
The ISO/IEC-test charts according to ISO/IEC 15775 and DIS ISO/IEC 19839-1 to -4 with german text: IG13
The DIN-test charts according to DIN 33866-1 to -5 with german text: DG13
The DIN-test charts according to DIN 33866-1 to -5 with english text: DE13

Digital Asian ISO/IEC-test charts with english text: http://www.jbmia.or.jp/~isoiec/sc28/testchart/index.htm

change to DE (information about DIN 33866-1 to 5: 2000-07 in english)
change to DG (information about DIN 33866-1 to 5: 2000-07 in german)
change to IE (information about ISO/IEC 15775: 1999-12 and DIS ISO/IEC 19839-1 to 4: 2000-04 in english)
change to IG (information about ISO/IEC 15775: 1999-12 and DIS ISO/IEC 19839-1 to 4: 2000-04 in german)

go to DE.HTM